RESUMO

INTRODUÇÃO: Vários preparados podem ser utilizados na citologia diagnóstica, como esfregaços (SM), preparados do tipo meio líquido (ML) e emblocado em parafina ou cell block (CB).
OBJETIVO: Avaliar a qualidade do CB, além dos espécimes citológicos convencionais, em casos de biópsia aspirativa por agulha fina (BAAF) de nódulos de tireoide na rotina diagnóstica. Método: Cento e seis casos consecutivos de BAAF de nódulos de tireoide foram avaliados independentemente por dois citopatologistas (Obs1 e Obs2) quanto à celularidade dos preparados de SM, ML e CB.
RESULTADOS: A celularidade foi rica/moderada em 56 (52,8%) CB para ambos observadores. ML mostrou celularidade rica/moderada em 86 (81,1%) casos para o Obs1 e 91 (85,8%) para o Obs2; desses casos, CB mostrou a mesma celularidade em 52/86 (60,4%) casos para o Obs1 e 54/91 (59,3%) para o Obs2. SM mostrou celularidade rica/moderada em 86 (81,1%) casos para o Obs1 e 87 (82%) para o Obs2; desses casos, CB apresentou a mesma celularidade em 48/86 (55,8%) casos para o Obs1 e 54/87 (62%) para o Obs2. A celularidade do CB foi maior do que a do ML em apenas cinco casos para o Obs1 e três para o Obs2. ML foi avaliado como escasso/ausente em apenas cinco (4,7%) e seis (5,6%) casos para os Obs1 e Obs2, respectivamente.
CONCLUSÃO: CB pode ser utilizado rotineiramente como espécime adicional no material obtido de BAAF de nódulos de tireoide, sem prejuízo dos espécimes de meio líquido, o que possibilita a realização de estudo complementar, principalmente imuno-histoquímico e molecular.

Palavras-chave: glândula tireoide; biópsia aspirativa por agulha fina; técnicas citológicas.

ABSTRACT

INTRODUCTION: Various preparations can be used in diagnostic cytology, including conventional smears (CS), liquid-based preparations (LBP) and cell block (CB).
OBJECTIVE: The aim of this study is to evaluate the quality of CB preparations in addition to conventional cytological specimens in cases of fine-needle aspiration biopsy (FNAB) of thyroid nodules in diagnostic routine. Method: One hundred and six consecutive cases of FNAB routine thyroid nodules were independently evaluated by two cytopathologists (Obs1 and Obs2) on the cellularity of SM, LBP and CB.
RESULTS: The cellularity was rich/moderate in 56 (52.8%) CBs for both observers. LBP showed rich/moderate cellularity in 86 (81.1%) cases for Obs1 and 91 (85.8%) for Obs2; among these cases, CB showed the same cellularity in 52/86 (60.4%) cases for Obs1 and 54/91 (59.3%) for Obs2. SM showed rich/moderate cellularity in 86 (81.1%) cases for Obs1 and 87 (82%) for Obs2; among these cases, CB showed the same cellularity in 48/86 (55.8%) cases for Obs1 and 54/87 (62%) for Obs2. CB cellularity was higher than that in LBP in only five cases for Obs1 and three for Obs2. LBP was assessed as low/absent in only five (4.7%) and six (5.6%) cases for Obs1 and Obs2, respectively.
CONCLUSION: CB can be routinely used as additional specimen in material obtained from thyroid nodules FNAB, without adversely affecting LBP specimens, enabling the conduction of further immunohistochemical and molecular studies.

Keywords: thyroid gland; fine-needle aspiration biopsy; cytological techniques.